logo
Home ProductsOn Site Sodium Hypochlorite Generation

400G/H On Site Sodium Hypochlorite Generation With 0.8 % Concentration For Disinfection

400G/H On Site Sodium Hypochlorite Generation With 0.8 % Concentration For Disinfection

    • 400G/H On Site Sodium Hypochlorite Generation With 0.8 % Concentration For Disinfection
    • 400G/H On Site Sodium Hypochlorite Generation With 0.8 % Concentration For Disinfection
    • 400G/H On Site Sodium Hypochlorite Generation With 0.8 % Concentration For Disinfection
  • 400G/H On Site Sodium Hypochlorite Generation With 0.8 % Concentration For Disinfection

    Product Details:

    Place of Origin: CHINA
    Brand Name: CNJS
    Certification: ISO9001
    Model Number: CNJS-S-400

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 SET
    Price: NEGOTIATION
    Packaging Details: wooden case
    Delivery Time: 7-15 work days
    Payment Terms: L/C, T/T, Western Union
    Supply Ability: 100 SETS /month
    Contact Now
    Detailed Product Description
    Available Chlorine: 0.8% Inlet Water Temperature: 5-27℃
    Inlet Water Pressure: 0.2-0.4Mpa Electrolytic Liquid: 2.5~3% Weak Brine
    Content Available CL: 7000~9000ppm Rated Current: Determined According To The Selected Product Model
    Working Way: 24 Hours Automatic Market: Globle
    Highlight:

    Hypochlorite Generator Sea Water

    ,

    Onsite Sodium Hypochlorite Generation System

    400G/H On Site Made Chlorine With 0.8 % Concentration For Disinfection

     


    Technical parameters :

     

    Type :CNJS-S 400

     

    Available chlorine ( g/ h) : 400

     

    Flow ( L/h) :50

     

    Salt consumption ( kg /h ) :1.4

     

    Rated power (kw) :2.3

     

    Size (mm)( L×W×H) :900*1400*1100

     


    Product feature:

     

     

     

     

    Chlorine concentration brine

     

     2.5%

     

    Power consumption 

     

    less than 4.5KW/ kg

     

    Content available CL

     

    7000~9000ppm

     

    Working way

     

    Unattended , fully automatic operation

     

    Life expectancy of anode coating

     

    more than 5 years, and anode coating can be coated and used repeatedly

     

    Life expectancy of the electrode plates

     

    more than 20 years      

     

    Life expectancy of whole machine

     

    more than 15 years 

     

     

     

    Principle :

     

     

    the main role of sodium hypochlorite disinfection is through its form hypochlorous acid hydrolysis, hypochlorous acid further break down to form new ecological oxygen [O] , new ecological oxygen strong oxidizing substances such as bacteria and virus on the protein denaturation, which kill pathogenic microbes.

     

     

    Second, hypochlorous acid in the process of sterilization, kill the virus, not only can be applied to the cell, the virus shell, and for small hypochlorous acid molecules, without charge, also can penetrate the bacteria (virus) in the body, and bacteria (virus) protein, nucleic acid and enzyme oxidizing reaction of organic polymer, so as to kill the pathogenic microorganisms.

     

     

    Again, hypochlorite produced chlorine ion can significantly change the bacteria and virus, the osmotic pressure of the body, make the loss of activity and cell death.

     

     

     

     

     

    Work flow chart :

    400G/H On Site Sodium Hypochlorite Generation With 0.8 % Concentration For Disinfection

     

     

    Product system

     

     

     

     

    Filter part  : 

     

    Secondary PP material , 5 um level precision filter, salt can be completely filtering impurities.

     
    Dosing part :
     
    Mainly includes dosing pump

     

    Electrode part :

     

    Mainly includes the electrode slice and terminal

     

    Power part :

     

    Mainly includes the high frequency power switch and controller.

     

     

    The equipment safety reasons :

     

     

    The only needed raw material:

     
    Salt can be safe and convenient transportation , storage , without any volatile and other toxic , no focus on chlorine needed hazards monitoring requirements on terror

     

    Using DC low voltage electrolytic process , there is no high pressure , steam and heat hazards

     

     

    If the sodium hypochlorite generator machine got a failure, just stop it and not damage on the surrounding       equipment , staff or any surrounding residents.

     

     

    400G/H On Site Sodium Hypochlorite Generation With 0.8 % Concentration For Disinfection

     

     

    Contact Details
    Shanghai Jiashang Environmental Technology Co., LTD

    Contact Person: Mrs. Sherry

    Tel: 86-21-64760106-9:00

    Fax: 86-21-64760107

    Send your inquiry directly to us (0 / 3000)

    Other Products

    Contact

    Address: RoomA206 No.455 Xiangmin Rd, Songjiang District, Shanghai , China

    Factory Address:RoomA206 No.455 Xiangmin Rd, Songjiang District, Shanghai , China