logo
Home ProductsHypochlorite Generation From Seawater

Customied High Throughput Hypochlorite Generation From Seawater 5000 kg / h

Customied High Throughput Hypochlorite Generation From Seawater 5000 kg / h

    • Customied High Throughput Hypochlorite Generation From Seawater 5000 kg / h
    • Customied High Throughput Hypochlorite Generation From Seawater 5000 kg / h
  • Customied High Throughput Hypochlorite Generation From Seawater 5000 kg / h

    Product Details:

    Place of Origin: CHINA
    Brand Name: CNJS
    Certification: ISO9001
    Model Number: CNJS-SW5000

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 SET
    Price: NEGOTIATION
    Packaging Details: wooden case
    Delivery Time: 35 work days
    Payment Terms: L/C, T/T, Western Union
    Supply Ability: 5 SETS PER MONTH
    Contact Now
    Detailed Product Description
    Available Chlorine:: 2000 -3000mg/L Design Pressure: 0.45 Mpa
    Inlet Water Pressure: 0.2-0.4 Mpa Acid Cleaning Period: 1-12 Months
    DC Power Consumption: 3.7 K W H / Kg Cl2
    Highlight:

    Hypochlorite Generator Sea Water

    ,

    Sodium Hypochlorite Generator

     

    Customied High Throughput Hypochlorite Generation From Seawater 5000 kg / h 

     

     

    Product introduction :

     

    Technical parameters:

    Type

    Available

    Cl2

    (Kg/h)

    Flow

    water (m3/h)

    AC

    consumption

    (kw )

    Av Cl2

    Concentration

    (ppm)

    Treatment of Cooling Water

    Dosing

    Rate

    (ppm)

    Cooling Water Flow

     (m3/h)

    CNJS-SW-5000

    5

    5

    20.6

    1000

    1

    5,000

     

     

    Generation principle :

      the sodium chloride solution under the certain voltage effect of the cell, a series of electrochemical reaction within the cell and the resulting solution is the NaClO solution. The main process can be simplified as follows:

     

     

    Customied High Throughput Hypochlorite Generation From Seawater 5000 kg / h

     

     

    • Application  :
    • Extensive use of seawater as cooling water such as: petroleum chemical plants, steel plants, thermal power stations and other coastal and marine plants.
    • Seawater as raw material can simply generate the required amount of sodium hypochlorite. Water electrolysis device can applied in many areas. And also in the field of water treatment oxidation and disinfection by sodium hypochlorite.

    The characteristics of the electrolytic cell:

    Bipolar・transparent electrolytic cell

     

    Customied High Throughput Hypochlorite Generation From Seawater 5000 kg / h

     

    Titanium copper composites conduction

    Less resistance

    Electrodes arranged in series

    Compact and lightweight

    Demountable electrode

    Easily replaced

    Horizontal cylindrical cell

    Compact and simple

     

     

    Corrosion-resistant material

    Customied High Throughput Hypochlorite Generation From Seawater 5000 kg / h

    Cathode

    2 mm titanium plate

    Corrosion-resistant

    Frame body

    PVC

     

    Corrosion-resistant PVC material

    Frame cover

    PVC

    Gasket

    PVDF

    Replace in the same period with the electrode

    Power supply terminal

    Titanium

    Titanium and copper composite material

    Corrosion resistant

     

     

     Long-term stability

     

     

    Electrodes arranged in series

    The electrolytic cell liquid flowing smoothly

    Prevent scaling

    Supply new

    liquid

      Maintain the

      coating state

     Ensure

     electrolysis condition

    Long-term stablility

    Frame diameter moderate

    Prevent one-way flow and make sure uniform flow between electrodes

    Moderate cross-sectional shapes

    liquid supply process

    Supply new liquid to the electrodes

    Gas path

    Supply new liquid to the

    electrodes

    Cycle way

    To make sure a proper flow rate in the cell

    High corrosion resistance

    High performance

    Long electrode life

    Maintain long-term stable electrolysis

    performance

    Avoid failures

        

    Long-term

    stability

    Fewer gasket

    Operation without leakage

    Electrode flange one-piece

    Pipe pressure ability strong, reduce leakage

     

     

    Good maintainability

     

    Customied High Throughput Hypochlorite Generation From Seawater 5000 kg / h

     

    Electrode shape

    Demountable

    Easy to loading and unloading  the electrode

    Accessories specifications

    Standard Parts

    Procurement convenience

    Frame

    Outer material is alumina

    Long as new

     

     

    Easily to clean the electrode

     

    Customied High Throughput Hypochlorite Generation From Seawater 5000 kg / h

    Acid cleaning device

    Portable acid cleaning device

    Without removing the

    cell and easy to cleaning the electrode

    Clean the nozzle

    Set the cleaning nozzle at the entrance of electrolytic cell

     

    Other advantages and features:

    1.CNJS use the seawater as the raw material, make the required amount of sodium hypochlorite.

    2.CNJS on –site no need for storage or transportation of dangerous chemicals.

    3.Recently by adding medicine to prevent adhere of marine organisms, and the economy effect is not well, thus attracting more attention on seawater electrolysis.

     

     

    Compared with the previous forms of disinfection:

     

     

    Customied High Throughput Hypochlorite Generation From Seawater 5000 kg / h

     

     

    Measure(before)

    Inject of chlorine or commercial

    sodium hypochlorite

     

     

    Problem

     

    Liquid chlorine :

    suffered the risk of leakage                                                                                                                                                                                       Customied High Throughput Hypochlorite Generation From Seawater 5000 kg / h              Using CNJS seawater equipment   Commercial sodium hypochlorite :                                             can solve all  the problems.             Long-term storage, the concentration will decline.             

     

     

    Acid cleaning effect

     

    Keep the current efficiency:

    After removing the dirt from the adhere of the electrode, can keep the electrolyzing body performance well and high efficiency to produce sodium hypochlorite.

    By removing dirt to prevent the consumption of anodic coating:

    By removing dirt prevents the base composition of the anode coating and anode material consumption and damage, extended electrode life.

    Energy-saving operation:

           After removal of dirt and impurities, the voltage decreases, reducing power consumption.

    Contact Details
    Shanghai Jiashang Environmental Technology Co., LTD

    Contact Person: Mrs. Sherry

    Tel: 86-21-64760106-9:00

    Fax: 86-21-64760107

    Send your inquiry directly to us (0 / 3000)

    Contact

    Address: RoomA206 No.455 Xiangmin Rd, Songjiang District, Shanghai , China

    Factory Address:RoomA206 No.455 Xiangmin Rd, Songjiang District, Shanghai , China